sql

DDS CAL3K-A Oxygen Bomb Calorimeter System

Rp. 100
Last Updated
16 Mar 2023
Country Origin
Indonesia
Minimum Order
1 Unit

Specification of DDS CAL3K-A Oxygen Bomb Calorimeter System

Description

CAL3K-A Oxygen Bomb Calorimeter System

The CAL3K-A is the companion to the CAL3K-AP, but with external oxygen filling. This instrument was designed for rough production environments where the automatic filling is not desired.

APPLICATION : The CAL3K-A uses a combination of the Isothermal and Adiabatic calorimetry methods, while still using the dry method, i.e. it is waterless. The minimum determination time is down to 4.5 minutes.

 

MORE ACCURATE RESULTS IN MINUTES - The CAL3K-A is one our faster calorimeter systems and is ideal for high sample throughput with more than 10 samples per hour. It uses a combination of the Isothermal and Adiabatic calorimetry methods and is still waterless. The minimum determination time is as little as 4.5 minutes per sample. The CAL3K-A makes use of the external oxygen filling station, bayonet bomb vessel and air cooler with the calorimeter. The CAL3K-A is the brother of the CAL3K-AP system, the major difference being the manual oxygen filling. This instrument has all the features of the CAL3K-AP, but avoids the potential trouble of leaking oxygen valves and fittings, and the associated maintenance. It can be operated in the Dynamic (Isoperibol), Isothermal, Adiabatic and Experimental modes, but requires calibration in each mode. The vessel is filled with oxygen in an EXTERNAL filling station which has a flow restriction and oxygen filter.

 

CAL3K-A OXYGEN BOMB CALORIMETER SYSTEM

The CAL3K-A conforms to ASTM D5865-12, ASTM D4809-13, ISO 1928-2009, and DIN 51900-2 international standards. The CAL3K bomb calorimeter uses the isothermal, adiabatic or isobatic calorimetry methods to measure temperature readings and to calculate the result in MJ, BTU or Calories.

The bomb vessel has been upgraded to include a self-locking and sealing bayonet vessel with built-in temperature sensors. The vessel is completely removable for easy sample management, cooling, cleaning and maintenance. Multiple vessels can be used in the same calorimeter, each with their own temperature calibration curves. Multiple vessels improve sample throughput and provides a higher redundancy should a vessel fail. While one vessel is in the calorimeter, the other can be cooled and prepared with the next sample.

The CAL3K-A calorimeter interfaces with different devices, including PC (PC Software), Balance, Printer and Bluetooth (Wireless). The unit also integrates fully with software based laboratory and information management systems (LIMS) and has a statistical print output in addition to the real time output.