PT ANDALAN BANGUN SEJAHTERA

sql
Fluke 902 FC True rms HVAC Clamp Meter
Hover to Zoom

Last Updated
14 Sep 2020
Country Origin
United States
Minimum Order
1 unit

Specification of

Alat Laboratorium Umum

SPECIFICATION Fluke 902 FC True rms HVAC Clamp Meter

Function
A ac (via Jaw)

Resolution 0.01/0.1 A

Accuracy 2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)

Range 60.00/600.0 A
Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A
3.0 MIN@180 A
> 1.4 MIN@600 A
Add 2% for CF>400 A

V ac
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V

V dc
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
Ohms
Resolution 0.1/1/10
Accuracy 1% ±5 digits
Range 600/6000/60.00 kΩ
Capacitance
Resolution 0.1/1 µF
Accuracy 1% ±4 digits
Range 100.0/1000 µF
µA
Resolution 0.1 µA
Accuracy 1% ±5 digits
Range 200 µA
Contact temperature
Resolution 0.1 C/F
Accuracy 1% ±8 digits
Range -10 to 400 °C (14 °F to 752 °F)
Continuity beeper
Beeper volume 75 dBA nom. 15 cm. from case front
On threshold <=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
O

perating humidity Non condensing

(< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104°F to 122 °F))

Altitude Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)

Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)

Weight (meter only) 419 g (15 oz)
Safety

IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V

IP Rating IEC 60529: IP30, non-operating

Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE

Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR

11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47

CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot