sql

Hach ONLINE 1720E Turbidimeter With sc200 Controller 2 Channel

Rp. 123
Last Updated
29 Jan 2024
Minimum Order
1 Unit

Accuracy

±2% of reading or ±0.02 NTU (whichever is greater) from 0 to 40 NTU

Accuracy 2

±5% of reading from 40 to 100 NTU (Defined according to ISO 15839.)

Alarm

When connected to sc controller: three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac

Certifications

Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1

Communication

When connected to sc controller: MODBUS RS232/RS485, PROFIBUS, HART

Compliance Certifications

Standard Methods 2130B, USEPA 180.1, Hach Method 8195

Dimensions (H x W x D)

254 mm x 305 mm x 406 mm

Mounting

Turbidimeter body and head assembly: wall and floor stand; sc controller: wall, pole, panel, and floor stand

Number of Channels

2

2

Operating Humidity

5 to 95 % non-condensing

Operating Temperature Range

0 to 40 °C (Double Sensor System)
0 to 50 °C (Single Sensor System)

Output

Up to five selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc Controller
Up to five selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc Controller

Power Requirements (Hz)

50 - 60 Hz

Power Requirements (Voltage)

115 - 230 V AC

Range

0.001 to 100 Nephelometric Turbidity Units (NTU)

Repeatability

Better than ± 1.0 % of reading or ±0.002 NTU, whichever is greater (Defined according to ISO 15839.)

Resolution

0.0001 NTU up to 9.9999 NTU; 0.001 NTU from 10.000 to 99.999 NTU; 0.01 NTU at 100.00
NTU

Response Time

Initial response in 1 minute, 15 seconds for a full-scale step change

Sample Flow Rate

200 to 750 mL/minute (3.1 to 11.9 gal/hour)

Sample Input

1/4 inch NPT female, 1/4 inch compression fitting (provided)

Sample Output

1/2 inch NPT female, 1/2 inch hose barb (provided)

Sample Temperature

 

0 to 70 °C (32 to 122°F)

Ship Wt. (lbs)

1720E Turbidimeter: 5.9 kg (13 lbs.)
1720E Turbidimeter and sc200 Controller:
6.12 kg (13.5 lbs.)

Signal Average Time

User selectable from 0, 6, 30, 60, 90 seconds

Storage Conditions

-20 to 60 °C (-4 to 140 °F)

Alat Laboratorium Umum

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0