PT ANDALAN BANGUN SEJAHTERA

sql
Haz-Dust EPAM-5000 Particulate Air Monitor
Haz-Dust EPAM-5000 Particulate Air Monitor
Hover to Zoom

30 Oct 2018
United States
1 unit
IDR 01

Specification of

Haz-Dust EPAM-5000 Particulate Air Monitor

Gas Analyzers

HAZ-DUST EPAM 5000

EPAM 5000 which is provided with DUSTComm Professional software, a strong battery life allowing for 24 hours of continuous sampling, and a memory capable of storing 15 months of monitoring data.

As a portable microprocessor-based particulate monitor, the HAZ-DUST EPAM 5000 is suitable for use in environmental, ambient and indoor air quality investigations. This monitor is highly sensitive and uses light scattering to measure particle concentration and provide immediate real-time determinations and data recordings of airborne particle concentration in mg/m3. There are interchangeable size-selective sampling heads which allow PM10, PM2.5, PM1.0 or TSP monitoring. The EPAM-5000 has a unique aero-dynamic particle sizing. The 47mm in-line filter holder loaded with the appropriate filter provides concurrent gravimetric sampling. On one battery you can sample for up to 24 hours. You can store up to 15 months of monitoring data. For further analysis you can download the data onto a PC using the included DUSTComm Professional software. Management ready reports and trend analysis can also be generated. The EPAM-5000 can interface with the VDM-7500 wireless video dust exposure monitoring system.

HAZ-Dust EPAM 5000 Features

  • Fast, easy setup
  • Highly sensitive and accurate
  • 0.001 to 20.0 mg/m3 for particles 0.1 to 100 μm
  • Optional 0.01 to 200 mg/m3 range available
  • Accuracy ± 10% to NIOSH Method 0500 using SAE fine test dust
  • High correlation to EPA PM10 methods and TEOM®
  • Ideal for saturation sampling
  • Internal air sample pump for 4.0 L/min flows*
  • Unique aerodynamic particle-sizing real-time sensor
  • Use optional EPA FRM-style cassette holder for gravimetric reference
  • Immediate display and data storage
  • Internal temperature compensation for ambient use
  • Interchangeable size-selective sampling heads for EPA parameters
  • PM10, PM2.5, PM1.0, and TSP
  • Rechargeable lead-acid battery for up to 24-hour operation
  • Continuous monitoring with AC adapter
  • Easy four-key menu-driven operation
  • Stores up to 15 months of data
  • RS232 digital output
  • Easy-to-use DustComm Pro data analysis and reporting software included
  • Portable and compact
  • 6 x 14 x 10 inches (15.2 x 35.6 x 25.4 cm)
  • 12 pounds (5.4 kg)
  • RFI/EMI shielded; CE marked
  • Real-time clock and data display
  • User-programmable start and stop time for unattended data collection
  • On-screen user-selectable sampling parameters retained in memory for quick, easy deployment when sampling parmeters remain unchanged
  • Wireless data transmission option transmits data up to 5 miles


 

Improved DustComm Pro PC Software provides:

  • Greater flexibility in graphical reports — create and label in new “draw and paint” program
  • Basic trend analysis
  • Live data feed and logging from wireless data transmission
  • Interfaces with the VDM-7500 wireless video exposure dust monitoring system
  •  

EPAM 5000 Applications:

  • Quantifying off-site particulate migration
  • Surveying for PM2.5 and PM10
  • Monitoring dust generation during drilling and excavation
  • Evaluating dust suppression and engineering controls
  • Locating and identifying “hot spots”
  • Emergency response and fugitive emissions compliance
  • Determining level of respiratory protection
  • Survey of workplace for OSHA/EPA compliance
  • Evaluating worker exposure to airborne contaminants
  • Dust collector/ventilation system checks
  • Monitoring lung-damaging particles in factories and buildings
  • Complementary instrument for all EPA and OSHA personal and ambient particulate air sampling procedures

Specifications

Technical Specification

Sensing Range0.001 to 20 mg/m3 
0.01 to 200 mg/m3 (optional)
Particle Size Range0.1 to 100 μm
Precision± 0.003 mg/m3 (3 μg/m3)
Accuracy± 10% to NIOSH Method 0500 using SAE fi ne test dust
Sampling Flow Rate4.0 L/min with variable adjustment
Filter Cassette Holder47mm
Alarm Output90 dB at 3ft
Analog Output0 to 4 VDC
Recording Time1 sec to 15 mos
Sampling Rate1 sec, 10 sec, 1 min and 30 min
Data Storage21, 600 data points
Security Code4 digit combinations
Memory and Time Storage> 10 years
Data DisplayConcentration in mg/m3 and TWA, MAX, MIN, STEL, Date and Time
Digital OutputRS-232
Operating Temperature-10 to 50 C
Storage Temperature-20 to 60 C
PowerRechargeable Lead-Acid Battery
Operating Time≥ 24 hrs
Charging Time10 to 12 hrs
Dimensions (case)6 x 14 x 10 inches ( 15.2 x 35.6 x 25.4 cm)
Weight12 lbs (5.4kg)

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot