PT ANDALAN BANGUN SEJAHTERA

sql
HI 351202
Hover to Zoom

Last Updated
25 Feb 2019
Country Origin
American Samoa
Minimum Order
1 UNIT

Specification of

Description

Hanna Hanna HI 3512-02 Calibration adalah 2 channel bangku profesional top meter dengan grafis LCD, dirancang untuk memberikan hasil laboratorium yang akurat.

Channel 1 memiliki kemampuan pH / ORP / ISE dan suhu pengukuran, sedangkan saluran 2 langkah EC / TDS / NaCl / Tahanan dan suhu.

Hanna Hanna HI 3512-02 Calibration log-on demand hingga 400 sampel dan juga menyediakan dipilih pengguna ‘dari kalibrasi range’ peringatan.

features Hanna Hanna HI 3512-02 Calibration

  • Up to five point pH calibration with seven standard buffers
  • Up to five point ISE calibration with six standard solutions
  • 0.001 pH resolution
  • GLP features
  • Automatic Temperature Compensation
  • PC interface via USB
  • Log on demand of up to 400 samples

Supplied with

  • HI-76310 conductivity/TDS probe
  • HI-1131B pH electrode
  • HI 7662-T temperature probe
  • Starter pack of buffer and cleaning solutions
  • HI-76404N electrode holder
  • 12Vdc adapter
  • Instructions

Hanna Instruments HI 3512 Dua Channel, pH / ORP / ISE, EC / TD / NaCl / Tahanan Benchtop Meter adalah 2 channel profesional benchtop meter dengan grafis LCD, dirancang untuk memberikan hasil laboratorium yang akurat. Channel 1 memiliki pH / ORP / ISE dan suhu kemampuan pengukuran sementara saluran 2 langkah EC / TDS / NaCl / Tahanan dan suhu. Saluran pH menawarkan hingga lima titik kalibrasi pH dengan tujuh buffer standar (pH 1,68, 4,01, 6,86, 7,01, 9,18, 10,01 dan 12,45) dan sampai dua buffer kustom.

Specifications Hanna Hanna HI 3512-02 Calibration

RangepH-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 16.000 pH
RangemV±2000 mV
RangeSelective Ions1.00 E-7 to 9.99 E10 conc.
RangeTemperature-20.0 to 120.0°C
RangeEC0.001 to 9.999 uS/cm; 10.00 to 99.99 uS/com; 100.0 to 999.9 uS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 999.9 mS/cm; 1000 mS/cm
RangeResistivity01.0 to 199.9 ohms; 100 to 1.999 ohms; 1.00 to 19.99 Kohms; 10.0 to 199.9 Kohms; 100 to 1.999 Kohms; 1.00 to 19.99 Mohms; 10.0 to 100.0 Mohms
RangeTDS0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L; 100.0 to 400.0 g/L
RangeSalinity% NaCl: 0.0 to 400.0%
ResolutionpH0.1 pH; 0.01 pH; 0.001 pH
ResolutionmV0.1 mV
ResolutionSelective Ions3 digits 0.01, 0.1, 1, 10 conc.
ResolutionTemperature0.1°C
ResolutionEC0.001 uS/cm; 0.01uS/cm; 0.1 uS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
ResolutionResistivity0.1 ohm; 1 ohm; 0.01 Kohms; 0.1 Kohms; 1 Kohms; 0.01 Mohms; 0.1 Mohms
ResolutionTDS0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/L
ResolutionSalinity0.1%
AccuracypH±0.01 pH / ±0.002 pH
AccuracymV±0.2 mV
AccuracySelective Ions±0.5% of reading
AccuracyTemperature±0.2°C
AccuracyEC±1% of reading
AccuracyResistivity±1% of reading
AccuracyTDS±1% of reading
AccuracySalinity±1% of reading
BNC Inputs 1 for pH electrode + 1 for ISE electrode
Calibration Check yes
Relative mV Offset Range ±2000 mV
pH Calibration automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
ISE Calibration Automatic, up to 5 point with 6 memorized values (0.1, 1, 10, 100, 1000, 10000 ppm)
Temperature Compensation Automatic or manual, -20.0 to 120°C (-4 to 248°F)
pH Electrode HI 1131B, glass body, refillable, BNC + pin connectors, 1 m cable (included)
Temperature Probe HI 7662-T with 1 m (3.3′) cable (included)
Input Impedance 1012
Log-On-Demand 400 samples
Power Supply 12 Vdc adapter (included)
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 235 x 207 x 110 mm
Weight 1.8 kg (4.0 lb.)

 

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot