AC Current Probe Model MN185
The MN185 is a high accuracy mini probe for measurements to 120AAC. This probe uses a special magnetic core to provide higher accuracy and lower phase shift. The MN185 provides an output signal of 1mAAC/AAC. The output termination are standard 4mm banana jacks.
Specifications:
Maximum Clamping Diameter | 0.47" (12mm) |
Current Range | 120Arms AC |
Measurement Range | 50mA to 120AAC |
Output Signal | 1mAAC / AAC (120mA @ 120A) |
Transformation Ratio | 1000:1 |
Output | 5 ft (1.5m) lead with 4mm safety banana plug |
Accuracy 50/60Hz | 1% R ± 0.01A (typical) |
Frequency Range | 30Hz to 10kHz |
Phase Shift at 50/60Hz | <3.5° |
Open Secondary Voltage | N/A |
Load Impedance | 5Ω max |
Weight | 5.6 oz (160g) |
Dimensions (HxWxD) | 1.26 x 4.5 x 0.87” (32 x 115 x 22mm) |
Operating Temperature | -13° to +122°F (-25° to +50°C) |
Storage Temperature | -40° to +176°F (-40° to +80°C) |
Rating | UL 94 V0 |
Safety | 250V working voltage, 30V max common mode between output and ground, 3kV 50/60Hz dielectric for 1mm.This probe is not CE marked. |